Interesting Pipeline Blowdown
Monday I needed to drain a produced water gathering system for
maintenance. This system is supplied by four gas wells with pump jacks
on them. The pump jacks discharge directly into the gas gathering
system (so they can overcome any system pressure encountered). Three
wells flow together in a 2-inch Performance Pipe (spoolable composite)
system that terminates at the fourth well and changes to 4-inch
Performance Pipe and flows 1 mile into atmospheric tanks and has an
elevation change of +200 ft.
The four wells together flow 600
bbl/day of produced water (17.5 gpm). This very small volume flow rate
in a 4-inch very smooth pipe should develop less than 1 psi of pressure
drop due to friction. The elevation change should cause the head of the
4-inch to be around 85 psig. Actual pressure at the head of the 4-inch
was 420 psig. The volume of the pipeline is just under 100 bbl.
At
9:00 am we started blowing the system down into an empty atmospheric
tank through a 2-inch line. This line bucked and rumbled for four hours
with steadily decreasing pressure and at 13:00 we had recovered 75 bbl
and the pressure was under 20 psig (minimum on the gauge we were using)
and flow became very intermittent. At that point we decided to break a
flange on the 4-inch and see if we could flow the rest of the water into
a prepared catchment. When we got the top half of the bolts removed we
had an ear-splitting noise of gas escaping and water shooting 50 ft in
the air. This went on intermittently for two more hours.
I
calculated blowdown time for the line being gas full at 420 psig and got
46 minutes. Drain time for liquid full was about an hour. Anybody
have a theory why the gas/water mixture blew hard for 6 hours?
The
purpose of draining the system was to install a gas knockout. We
installed it Tuesday morning and put the wells back on (with the gas
knockout bypassed waiting for electrical connection). By this afternoon
the pressure in the system was back up to 420-430 psig. Late this
afternoon we put the gas knockout in service and it is shifting
considerable gas to gas sales instead of to the 4-inch. After 15
minutes in service the line pressure dropped to 350 psig. Can't wait to
see what it is in the morning.
First, why did you open it up without knowing whay there was 420 psi there when you thought it should only have been 80?
Sounds
like you were moving a sand plug and then the sand broke loose??? In
South Texas, we'd get those lines showing 0 psi, until the sand broke
loose somewhere. Super dangerous to open them up. Before I got there
an operator was killed when he opened up a sand trap valve(ball valve) and got no
flow, until he decided to look inside the opened valve.