Can anyone tell me the difference in API607 IV edition and API6FA for fire safe testing?

API 6FA applies to API 6A and 6D valves.  API 607 applies to soft-seated quarter-turn valves.

API 6FA applies to quarter turn soft seated valves as covered in API 6D - Pipeline Valves includes ball and plug valves.  

API has 2 divisions - Production and refining.  API 6FA and 6D are from the division of Production and API 607 and 608 are from the division of refining.

API 6FA PALES in comparison to the API 607 Firesafe regulations.

Do the homeworkand see that if a Valve Complies with 607 (4th edition- Basically the Exxon partial burn test) then that valve would LAUGH at meeting 6FA standards.